AutoTask has very flexible scheduling and conditional triggers for running various task. Smart Updater can update multiple files at once without comparing them; the. The cost-effective Powerware 5115 uninterruptible power system. Sized businesses, the Powerware 5115 UPS features both USB and serial ports to facilitate.

Download software and firmware Whether you’d like to monitor a single UPS or help with managing your entire virtualized network, Eaton has a monitoring and management software solution. From monitoring event history, notifying you of alerts and delivering real-time status, Eaton software provides the tools you need to keep your critical equipment running at all times. Our software solutions are easy to use and maintain business continuity which saves time, saves money and reduces risk. Use the drop down menus below to select a specific product to see related software and firmware solutions or filter the results using the “solution type” drop down to show only software, firmware or legacy software. Or select your software solution: View a complete listing of our software & firmware products.

. POWERWARE 5115A USB ® User’s Guide 500-1400 VA www.powerware.com.au.

Eaton’s Powerware Division, trading in Australia as Eaton Power Quality Pty Ltd Powerware is a registered trademark and Advanced Battery Management (ABM) is a trademark of Powerware Corporation. 5115AUSBManual.qxd Rev 1 © Copyright 2004, Powerware. All rights reserved. POWERWARE 5115A USB ® 500-1400 VA User’s Guide www.powerware.com.au. Special Symbols The following are examples of symbols used on the UPS to alert you to important information.

RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for additional information, such as important operating and maintenance instructions. Powerware 5115 -Introduction.1 Installation.3 Inspecting the Equipment.

Troubleshooting.25 Audible Alarms and UPS Conditions. With the Powerware 5115, you can safely eliminate the effects of power disturbances and guard the integrity of your equipment. The Powerware 5115’s flexibility to handle an array of network devices makes it the perfect choice to protect your LANs, servers, workstations and other electrical equipment. Powerware 5115 - Introduction Because an integral part of power protection is power management software, the Powerware 5115 comes fully equipped with a communication port, USB port, serial cable and a CD containing both LanSafe III for networked systems and FailSafe III for standalone systems. To comply with international standards, the sum of earth leakage current from the load connected to the UPS must not exceed 1.5 mA. ® Powerware 5115A USB User’s Guide SAVE THESE INSTRUCTIONS. Do not operate near water or.

USB port of UPS communication port using the supplied communication cable. Plug the power cord supplied into the input connector on the UPS rear panel. Plug the UPS power cord into a power outlet. Typical UPS Installation ® Powerware 5115A USB User’s Guide.

www.powerware.com.au. NOTE The batteries charge to 90% capacity in approximately 3 hours.

However, it is recommended that the batteries charge for 6 to 24 hours after installation or long-term storage. ® Powerware 5115A USB User’s Guide button as shown in Figure 2. Installation U P S R e a r P a n e l s This section shows the rear panels of the Powerware 5115 models. Communication Port Communication Port IEC 320 10A Input Connector Figure 3. 500VA Rear Panel Figure 4. 750VA Rear Panel ®.

Communication Port IEC 320 10A Input Connector Communication Port ® Powerware 5115A USB User’s Guide Figure 5. 1000VA Rear Panel Figure 6. 1400VA Rear Panel. www.powerware.com.au USB Port Network Transient Protector 3 x 10A Australian Output Receptacles USB Port.

®. Powerware 5115A USB User’s Guide www.powerware.com.au. Standby mode.

The battery recharges when necessary and the indicating that power is not available from the UPS output receptacles. ® Powerware 5115A USB User’s Guide button on the front panel (shown in Figure 7).

After button on the front panel and then unplug the UPS. NOTE The batteries must be fully charged and the UPS must not be in Battery mode to perform the self-test.

UPS Front Panel button for three seconds to initiate the self-test. If the UPS finds ® Powerware 5115A USB User’s Guide. www.powerware.com.au. The software polls the UPS for detailed information on the status of the power environment. If a power emergency occurs, the software initiates the saving of all data and an orderly shutdown of the equipment ® Powerware 5115A USB User’s Guide EATURES Figure 8. Communication Port.

Nch software. Connect the other end of the USB cable to the USB port on your computer. Install the LanSafe software and USB drivers according to the instructions provided with the Powerware Software Suite CD.

Function Low Battery relay contact; 20 mA, 30 Vdc contact. Connect the input connector of the equipment you are protecting in the jack labelled IN. Connect the output connector to the jack labelled OUT.

NOTE Do not connect or attempt to connect this connector to telephone circuits. ® Powerware 5115A USB User’s Guide Figure 10 Network Transient Protector. ®.

Powerware 5115A USB User’s Guide www.powerware.com.au. Check the battery recharge date on the shipping carton label.

If the date has expired and the batteries were never recharged, do not use the UPS. Contact your service representative. ® Powerware 5115A USB User’s Guide. www.powerware.com.au. DO NOT DISCONNECT the batteries while the UPS is in Battery mode. Pull the battery out onto a flat, stable surface.

The battery is unsupported when you pull it out of the UPS. WARNING CAUTION ® Powerware 5115A USB User’s Guide button and then. www.powerware.com.au. Pull the top left corner forward and remove the front panel. Slide up and remove the metal battery cover. Disconnect the red battery cable and then disconnect the black battery cable Pull the battery out onto a flat, stable surface. ® Powerware 5115A USB User’s Guide.

www.powerware.com.au. UPS Maintenance 750-1400VA units. Disconnect the red battery cable and then pull the battery out onto a flat, stable surface. Disconnect the black battery cable to the UPS as shown. ® Powerware 5115A USB User’s Guide.

www.powerware.com.au. Do not discard the UPS or the UPS batteries in the trash. This product contains sealed, lead-acid batteries and must be disposed of properly. For more information, contact your local recycling or hazardous waste centre.

® Powerware 5115A USB User’s Guide button for three seconds to initiate a self-test. The 15-second WARNING CAUTION. ®. Powerware 5115A USB User’s Guide www.powerware.com.au.

C H A P T E R 6 PECIFICATIONS This section provides the following specifications for the Powerware 5115 models:. Electrical input and output. Mass and dimensions. Environmental and safety. Battery Table 2. Model List and Mechanical.

Over 1,500 metres: 0 C to 35 C to 55 5-95% noncondensing Up to 3,000 metres above sea level Less than 45 dBA typical AS/NZS 61000.4.5 1999 Level 3 EN 50091-1-1 and IEC 60950 AS62040.2.2001 ® Powerware 5115A USB User’s Guide. www.powerware.com.au. 1200 1400 NOTE Battery times are approximate and may vary depending on the load configuration and battery charge. ® Powerware 5115A USB User’s Guide 500VA: (1) 12V, 9 Ah internal battery 750VA: (2) 12V, 7 or 7.2 Ah internal batteries.

Powerware 5115 Usb Driver5115

®. Powerware 5115A USB User’s Guide www.powerware.com.au.

(located on the rear of the unit) available. If the unit must be returned, Powerware will give you a Return Authorisation (RA) number. Phone Powerware National Service & Repair Centre on 1300 303 059 for an RA number before returning the unit for any reason.

2 minutes or less of battery power remains (depending on load configuration and battery charge). Prepare for a shutdown.Save your work and turn off your equipment.

The alarm cannot be silenced. ® Powerware 5115A USB User’s Guide button, if the alarm. www.powerware.com.au. Continuous UPS fan fault (750-1400VA beep models only) ® Powerware 5115A USB User’s Guide Action Correct the input voltage, if possible.

Eaton 5115 Ups

The UPS continues to operate on battery until the condition is corrected or the battery is completely discharged. Shutdown is imminent. Save your work and turn off your equipment. Turn off the UPS. Contact your service representative.

Save your work and turn off your equipment. Turn off the UPS. Contact your service representative.

® Powerware 5115A USB User’s Guide still. www.powerware.com.au. Powerware’ service technicians have in-depth knowledge of the UPS and power problems. Powerware may tell you the UPS must be returned. If this happens, we will give you a Return Authorisation (RA) number. When you return a Powerware 5115 to the factory for any reason, please use the original packing material in which your unit was shipped to you. ®.

Powerware 5115A USB User’s Guide www.powerware.com.au. High grade batteries, designated for Uninterruptible Power Supply (UPS) applications, are supplied by EPQ for use with Powerware UPS equipment. These batteries have a finite life expectancy depending on a number of variables, including rate of discharge, depth of discharge, operating temperature, etc. EPQ reserves the right to charge for replacement batteries if within the one year guarantee period replacement batteries are necessary as a result of misuse or misapplication by the purchaser or end user. ® Powerware 5115A USB User’s Guide.

Powerware 5115 battery replacement

Powerware 5115 Battery Replacement

www.powerware.com.au. Powerware Corporation's factory, for a charge pro-rated on the following basis. The user will be allowed a credit against the list price of equivalent equipment at the time of return to Powerware, in pro- portion to the percentage of the warranted service life remaining at the time of return to Powerware Corporation. For the lifetime of the original purchaser who has filed the Warranty Registration, Powerware promises to repair or replace (at Powerware's option) equipment (valued up to $50,000) that is damaged by an AC power line surge, spike, or other transient when properly connected to Powerware's UPS (reimbursement for or restoration of data loss excluded). Eaton Power Quality Pty Ltd 119-127 Wicks Road North Ryde NSW 2113 Phone: 61-2-9878 5000 Fax: 61-2-9887 2186 National Service and Repair Centre Web Site: www.powerware.com.au Customer Service Offices Adelaide PO Box 481, Marlestone Business Centre SA 5033 Phone: 08-8347-3622 Fax: 08-8445-6328.